Diesel Fuel
Nozzle Chart
(SC & HP Series with standard Hydro Tek coil)
| GPM |
140° rise |
150° rise |
BTU |
| 2 |
1.00
70° B |
1.00
70° B |
172,000 |
| 2.5 |
1.75
80° B |
1.75
80° B |
250,000 |
| 3 |
1.75
80° B |
1.75
80° B |
275,000 |
| 4 |
2.50
80° A |
2.50
80° A |
365,000 |
| 5 |
3.00
90° B |
3.00
90° B |
435,000 |
| 6 |
3.50
90° B |
3.50
90° B |
500,000
|
Nozzle
size x 140000= diesel fired BTU @ 100 psi fuel pressure.
°C=.555 (°F - 32) - °F=1.8(°C + 32)
|
Saturated Water Substance
(Boiling point of water at various pressures)
| P.S.I. |
Temperature |
| 30 |
250 |
| 100 |
327 |
| 500 |
467 |
| 3000 |
544 |
|
|
NG
Supply Pipe : 450,000
BTU
| Length
of run |
Pipe
Diameter |
| 0-50
ft |
1
1/4" |
| 51-150
ft |
1
1/2" |
| 151
- 200 ft |
2" |
|
Pipe
Friction Loss
Pressure
Loss in coils in PSI (aprox.)
| GPM |
Diesel
Fired |
Natural
Gas |
| 2 |
6 |
11 |
| 3 |
13 |
23 |
| 4 |
24 |
43 |
| 5 |
34 |
61.2 |
|